Thermal Cure

Revision as of 14:39, 4 September 2026 by Lorena (talk | contribs) (linked UV curing page for initial tack)

Bake Recipes

The following are recommended cure times and temperatures based on manufacturer's technical data sheet information. For hybrid materials, do UV initial tack before thermal bake for full crosslink.

Bake Recipes
Material Recommended Cure (Temp°C/Time) Alternate 1 Alternate 2 Alternate 3 Initial Tack
HYB-353ND 100°C/30 min 150°C/30 min 80°C/ 1 hour 100mW/cm2 for 1min
H70E 150°C/1 hour 120°C/30min 100°C/1 hour
H20E 150°C/1 hour 80°C/3 hours
GA700H 100°C/1 hour 150mW/cm2 for 2 min
3553-LV-UTF_HM 110°C/1 hour 1000mW/cm2 for 30 sec
CHIPSHIELD 2401 110°C/1 hour 1000mW/cm2 for 30 sec
OPTOCAST 3410 110°C/1 hour 1500mW/cm2 for 30 sec