UV Curing: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
mNo edit summary |
linked thermal cure page |
||
| Line 13: | Line 13: | ||
!Time |
!Time |
||
!LED Distance From Sample |
!LED Distance From Sample |
||
!Additional Heat Cure(Temp°C/Time) |
![[Thermal Cure|Additional Heat Cure(Temp°C/Time)]] |
||
|- |
|- |
||
|OG116-31 |
|OG116-31 |
||
Revision as of 14:40, 4 September 2026
Supplier's Recommended UV Intensity can be used as baseline. If another intensity is needed, us the following graphs to determine irradiation area and working distance.
UV Curing Recipes
Recipes for hybrid materials are for initial tack only. UV exposure and heat cure will typically be needed for 100% crosslink. Perform initial tack before thermal bake.
| Material | Supplier's Recommended
UV Intensity |
Controller Output | Time | LED Distance From Sample | Additional Heat Cure(Temp°C/Time) |
|---|---|---|---|---|---|
| OG116-31 | 100% | 330 sec | 1cm | ||
| HYB-353ND | 100mW/cm2 | 10% | 60 sec | 1cm | 100°C / 30 min |
| 3553-LV-UTF_HM | 1000mW/cm2 | 55% | 60 sec | 25mm | 120°C/30 min |
| CHIPSHIELD 2401 | 1000mW/cm2 | 55% | 60 sec | 25mm | 110°C/1 hour |
| OPTOCAST 3410 | 1500 mW/cm2 | 85% | 60 sec | 25mm | 110°C/ 1 hour |
| GA700H | 150 mW/cm2 | 10% | 120 sec | 25mm | 100°C/ 1 hour |