UV Curing Recipes

Recipes for hybrid materials are for initial tack only. UV exposure and heat cure will typically be needed for 100% crosslink.

UV Curing
Material Supplier's Recommended

UV Intensity

Controller Output Time LED Distance From Sample Additional Heat Cure(Temp°C/Time)
OG116-31 100% 330 sec 1cm
HYB-353ND 100mW/cm2 100% 60 sec 1cm 100°C / 30 min
3553-LV-UTF_HM 1000mW/cm2 100% 30 sec 1cm 120°C/30 min