Supplier's Recommended UV Intensity can be used as baseline. If another intensity is needed, us the following graphs to determine irradiation area and working distance.


UV Curing Recipes

Recipes for hybrid materials are for initial tack only. UV exposure and heat cure will typically be needed for 100% crosslink. Perform initial tack before thermal bake.

UV Curing
Material Supplier's Recommended

UV Intensity

Controller Output Time LED Distance From Sample Additional Heat Cure(Temp°C/Time)
OG116-31 100% 330 sec 1cm
HYB-353ND 100mW/cm2 10% 60 sec 1cm 100°C / 30 min
3553-LV-UTF_HM 1000mW/cm2 55% 60 sec 25mm 120°C/30 min
CHIPSHIELD 2401 1000mW/cm2 55% 60 sec 25mm 110°C/1 hour
OPTOCAST 3410 1500 mW/cm2 85% 60 sec 25mm 110°C/ 1 hour
GA700H 150 mW/cm2 10% 120 sec 25mm 100°C/ 1 hour