Supplier's Recommended UV Intensity can be used as baseline. If another intensity is needed,
[[File:Intensities graph.png|frameless|720x720px]][[File:ANUJ6170 UV Intensity Profile.png|frameless|645x645px]]
▲Supplier's Recommended UV Intensity can be used as baseline. If another intensity is needed, us the following graphs to determine irradiation area and working distance.
== UV Curing Recipes ==
Line 13:
!Time
!LED Distance From Sample
![[Thermal Cure|Additional Heat Cure(Temp°C/Time)]]
|-
|OG116-31
|100mW/cm2
|100%
|330 sec
Line 25:
|100mW/cm2
|10%
|60 sec
|1cm
|100°C / 30 min
Line 38:
|CHIPSHIELD 2401
|1000mW/cm2
|
|60 sec